Electroencephalographic records have been taken from deep regions of the brains of cats and monkeys with chronically implanted electrodes during centrifugal and shaking accelerations comparable to booster forces. Histological and X-ray controls have indicated that displacement of the electrodes does not occur, and that damage to brain tissue is comparable with nonaccelerated animals. A transistorized EEG amplifier suitable for recording in satellite biopack environments has been developed. In centrifuge tests, transverse accelerations up to 8 G were associated with rhythmic "arousal" patterns of slow waves in hippocampal regions of the temporal lobe during increasing or decreasing acceleration. Longitudinal accelerations between 5 and 6 G produced blackouts after 30 to 40 seconds, with flattening of EEG records, and frequently with induction of epileptic seizure activity in temporal-lobe leads. Shaking tests suggested that vibrational acceleration may be associated with the intermittent "driving" of the cerebral rhythms, in a fashion resembling photic driving, at shaking rates from 11 to 15 cps, and from 22 to 30 cps.