Key result
Cardiovascular magnetic resonance feature tracking demonstrated good to excellent inter-observer reproducibility for global circumferential strain (ICC 0.79) in a mouse model.
Why the study?
Does cardiovascular magnetic resonance feature tracking (CMR-FT) provide reproducible measurements of myocardial strain in a small animal model?
Does cardiovascular magnetic resonance feature tracking (CMR-FT) provide reproducible measurements of myocardial strain in a small animal model?
Effect estimate: ICC 0.79 (95% CI 0.46-0.91)
CMR-FT is a highly reproducible technique for assessing global circumferential and longitudinal strain in small animal models, allowing for small sample sizes in future preclinical trials.
Supports CMR-FT strain analysis in preclinical models; leaves open clinical translation pending human validation.
Cardiovascular magnetic resonance feature tracking (CMR-FT) is a novel tissue tracking technique developed for noninvasive assessment of myocardial motion and deformation. This preliminary study aimed to evaluate the observer’s reproducibility of CMR-FT in a small animal (mouse) model and define sample size calculation for future trials. Six C57BL/6 J mice were selected from the ongoing experimental mouse model onsite and underwent CMR with a 3 Tesla small animal MRI scanner. Myocardial deformation was analyzed using dedicated software (TomTec, Germany) by two observers. Left ventricular (LV) longitudinal, circumferential and radial strain (Ell LAX , Ecc SAX and Err SAX ) were calculated. To assess intra-observer agreement data analysis was repeated after 4 weeks. The sample size required to detect a relative change in strain was calculated. In general, Ecc SAX and Ell LAX demonstrated highest inter-observer reproducibility (ICC 0.79 (0.46–0.91) and 0.73 (0.56–0.83) Ecc SAX and Ell LAX respectively). In contrast, at the intra-observer level Ell LAX was more reproducible than Ecc SAX (ICC 0.83 (0.73–0.90) and 0.74 (0.49–0.87) Ell LAX and Ecc SAX respectively). The reproducibility of Err SAX was weak at both observer levels. Preliminary sample size calculation showed that a small study sample (e.g. ten animals to detect a relative 10% change in Ecc SAX ) could be sufficient to detect changes if parameter variability is low. This pilot study demonstrates good to excellent inter- and intra-observer reproducibility of CMR-FT technique in small animal model. The most reproducible measures are global circumferential and global longitudinal strain, whereas reproducibility of radial strain is weak. Furthermore, sample size calculation demonstrates that a small number of animals could be sufficient for future trials.
No takes yet. Share an insight, caveat, or question.
Lapinskas et al. (2017) studied Healthy (animal model) (n=6). Cardiovascular magnetic resonance feature tracking (CMR-FT) was evaluated on Inter-observer reproducibility of left ventricular short-axis circumferential strain (EccSAX) (ICC 0.79, 95% CI 0.46-0.91). Cardiovascular magnetic resonance feature tracking demonstrated good to excellent inter-observer reproducibility for global circumferential strain (ICC 0.79) in a mouse model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: