Direct injection h.p.l.c. methods for zaprinast, and pantoprazole and its sulphone metabolite were developed. 2. Optimal recovery of pantoprazole and its sulphone metabolite was effected by the absence of transfer losses and the effective adjustment of sample pH on-line. 3. Acetonitrile reduced the recovery of pantoprazole and its sulphone metabolite at acetonitrile concentrations greater than 5% in serum. 4. Direct injection h.p.l.c. methods minimize sample handling losses, reduce human contact with biological samples and are sufficiently accurate and reproducible to be used to support pharmacodynamic and toxicokinetic studies.
No takes yet. Share an insight, caveat, or question.
Doyle et al. (1992) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: