Why the study?
This study evaluates the impact of multi-use practices in CT and MEDRAD Centargo injectors equipped with Smart Protocols and other functionalities aimed at optimizing contrast media consumption, workflow efficiency, patient care time, and environmental sustainability.
Does the Centargo injector with Smart Protocols reduce contrast media usage and improve workflow efficiency compared to Stellant injectors in patients undergoing CT scans?
Does the Centargo injector with Smart Protocols reduce contrast media usage and improve workflow efficiency compared to Stellant injectors in patients undergoing CT scans?
The implementation of the Centargo injector with Smart Protocols significantly reduces contrast media volume, decreases radiographer time spent on non-value-added tasks, and lowers consumable waste in CT imaging.
May support lower contrast volume and workflow time with Centargo in CT; hypothesis-generating pending randomized confirmation.
This study evaluates the impact of Multi-use practices in computed tomography (CT) and MEDRAD® Centargo injectors equipped with Smart Protocols and other functionalities aimed for optimizing contrast media consumption, workflow efficiency, patient care time, and environmental sustainability at the CIMROD center. Data were collected across three measurement periods, assessing contrast volume per patient, distribution of activity on several tasks, injector preparation time, time for Iodinated contrast media documentation for traceability, and waste measurements. The Centargo injector equipped with Smart Protocols and kV optimization reduced contrast volume from a target of 80 mL to an average of 72.98 mL using Smart Protocols, then further optimized to 69.95 mL using kV optimization. Compared to previous injector generation, there was a decrease in non-added value tasks such as injector preparation time by 47.3%, measured with Udubu, or 72.35 s, measured by chronometer, per injected procedure. The multi-use implementation reduced waste production by 69% and 74%, respectively, for Centargo and Stellant multi-use versus single-use injectors. Even if the study has limitations, injectors such as Centargo equipped with Smart Protocols and other functionalities enhance operational and financial efficiency along with sustainability in radiology and contributes to clinical practice evolution.
No takes yet. Share an insight, caveat, or question.
Anquetil et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: