Key result
Google CT Foundation model achieves ~0.79 AUC for central PE detection but degrades externally.
Why the study?
Early detection of pulmonary embolism is critical for clinical outcomes, but existing deep-learning models often fail to generalize across institutions.
Does the Google CT Foundation model accurately detect central pulmonary embolism on CT pulmonary angiograms across different institutions?
Does the Google CT Foundation model accurately detect central pulmonary embolism on CT pulmonary angiograms across different institutions?
The Google CT Foundation model provides a baseline for central PE detection without fine-tuning, but its performance drops significantly on external validation, highlighting the need for further calibration or fine-tuning for cross-institutional reliability.
Early detection of pulmonary embolism (PE) is critical for clinical outcomes, yet existing deep-learning models often fail to generalize across institutions. The recently released Google CT Foundation model, pre-trained on a large, diverse CT corpus, produces compact volumetric embeddings that may transfer to downstream tasks without fine-tuning. We evaluate a classification pipeline that pairs these frozen embeddings with three lightweight heads - Multi-Layer Perceptron (MLP), Random Forest (RF), and a stacking ensemble - for central PE detection, training on the public RSNA CTPA dataset and externally validating on the Stanford INSPECT cohort. The pipeline first reproduces the published data-size scaling behavior of the foundation model on other medical pathologies. The highest point-estimate test AUC of 0.79 was obtained by the RF trained on a balanced training set of 408 CT studies and evaluated on the held-out RSNA test set of 144 studies; paired DeLong tests showed that this advantage over the MLP and stacking heads was not statistically significant. Direct comparison to specialized state-of-the-art PE pipelines is task-mismatched - those target any-PE rather than central PE - so the result anchors a non-fine-tuned baseline rather than a deficit. In a low-data regime, hard vascular segmentation did not improve performance. On the external INSPECT cohort, AUC dropped by 0.17 and specificity at the transferred operating point collapsed, so simple global threshold recalibration does not restore deployability-frozen generalist embeddings alone do not guarantee cross-institutional reliability.
No takes yet. Share an insight, caveat, or question.
Hosseinirad et al. (2026) studied central pulmonary embolism (n=552). Google CT Foundation model was evaluated on central PE detection (AUC) (AUC 0.79). The Google CT Foundation model with a Random Forest head achieved a test AUC of 0.79 for central pulmonary embolism detection, but performance dropped by 0.17 AUC on an external validation cohort.