Three Mg alloys, Mg-1.34% Ca-3% Zn (MCZ), Mg-1.34% Ca-3% Zn-0.2% Sr (MCZS), and Mg-2% Sr (MS), were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM) of alloy microstructure was performed to help interpret the results of the electrochemical testing. Results indicate that corrosion resistance of the alloys is as follows: MCZ > MCZS > MS.
No takes yet. Share an insight, caveat, or question.
Brooks et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: