This is the authors' abstract. We don't add key points for this paper.
A zero-cross detection algorithm was proposed for the cavity-length interrogation of fiber-optic Fabry-Perot (FP) sensors. The method can avoid the inaccuracy of peak determination in the conventional peak-to-peak method for the cavity-length interrogation of fiber-optic FP sensors caused by the slow variation of the spectral power density in peak neighboring regions. Both simulations and experiments were carried out to investigate the feasibility and performance of the zero-cross detection algorithm. Fiber-optic FP sensors with cavity lengths in the range of 150-1000 μm were successfully interrogated with a maximum error of 0.083 μm.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: