A method was established for the identification and quantification of carotenoids including geometrical isomers in fruit and vegetable juices by liquid chromatography with an ultraviolet-diode array detector, using a C(18) Vydac 201TP54 column. The mobile phase used was the ternary methanol mixture (0.1 M ammonium acetate), tert-butyl methyl ether and water, in a concentration gradient, and a temperature gradient was applied. Retinol palmitate was added as an internal standard. An extraction process (ethanol/hexane, 4:3, v/v) was performed, followed by saponification with diethyl ether/methanolic KOH (0.1%, w/v, BHT) (1:1, v/v) for 0.5 h at room temperature. Seventeen different (cis and trans) carotenoids were identified by UV-vis spectra and retention times in HPLC in the juices analyzed. The analytic parameters show that the method proposed is sensitive, reliable, accurate, and reproducible.
No takes yet. Share an insight, caveat, or question.
Cortés et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: