Key result
Simplified neurological scales miss disabling stroke deficits, with GCS yielding a ~56% false-negative rate.
Observational (n=172)
BACKGROUND: Scientific guidelines recommend the National Institutes of Health Stroke Scale for ischemic stroke assessment. However, many nurses find "slim" National Institutes of Health Stroke Scale versions or the Glasgow Coma Scale easier to use. OBJECTIVE: To compare 3 "slim" versions of the National Institutes of Health Stroke Scale and the Glasgow Coma Scale with the full National Institutes of Health Stroke Scale. METHODS: Components of the full National Institutes of Health Stroke Scale and Glasgow Coma Scale were abstracted from records of consecutive stroke patients. Items were subtracted from the full National Institutes of Health Stroke Scale, with items contained in "slim" versions retained. False-negative rates for neurological disability were calculated for the "slim" versions and the Glasgow Coma Scale. RESULTS: Data were collected from 172 acute stroke patients (median [interquartile range] 6 [3-12] for National Institutes of Health Stroke Scale, 15 [12-15] for Glasgow Coma Scale): 143 (83%) were ischemic stroke patients (27% posterior circulation strokes) and 29 (17%) were intracerebral hemorrhage patients. The value of "slim" scales and the Glasgow Coma Scale declined in a stepwise manner as the full National Institutes of Health Stroke Scale decreased because of false-negative results despite the presence of a measurable disabling deficit. False-negative rates were 5% to 19% on "slim" versions and 56% with the Glasgow Coma Scale. CONCLUSIONS: Use of "slim" scales, and in particular the Glasgow Coma Scale, substantially decreases the value of a structured neurological assessment, particularly in patients with low National Institutes of Health Stroke Scale scores.
No takes yet. Share an insight, caveat, or question.
Nye et al. (2012) conducted an observational in Acute stroke (ischemic stroke and intracerebral hemorrhage) (n=172). 3 'slim' versions of the National Institutes of Health Stroke Scale and the Glasgow Coma Scale vs. Full National Institutes of Health Stroke Scale was evaluated on False-negative rates for neurological disability. Slim NIHSS versions and the Glasgow Coma Scale yielded false-negative rates of 5% to 19% and 56%, respectively, for detecting disabling neurological deficits compared to the full NIHSS.
Synapse has enriched 5 related papers. Consider them for comparative context: