By using a recently developed theoretical model, which takes into proper account on a statistical basis the contributions to energy dissipation deriving from microscopic magnetization processes, a general loss expression is obtained, which permits one to compute total power losses, just knowing two parameters. These can easily be derived from a d.c. and a 50 Hz loss measurements in GO 3% SiFe, or from a single d.c. loss value and from the average grain size in NO 3%SiFe. The equation is used to compute total losses between d.c. and 100 Hz for peak inductions variable between 0.1 and 1.7 T in GO and NO laminations. Calculated losses are found to be in excellent agreement with experimental measurements performed on the studied materials over the same wide ranges of frequencies and peak inductions.
No takes yet. Share an insight, caveat, or question.
Bertotti et al. (1987) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: