Answers are grounded in this paper and cite their sources.
This paper presents a woodpecker-inspired shock isolation (SI) using a microgranular bed to protect micromachined electronic devices (MEDs) for high- g military applications where mechanical excitations reach up to tens of thousands of g s and several hundreds of kHz. The shock isolating phenomenon in the microgranular bed within a metal housing, biomimetically inspired from a spongy bone within a skull of the woodpecker, controls unwanted high-frequency mechanical excitations so that their adverse effects on the embedded MEDs are kept within acceptable limit. The microgranular bed composed of close-packed microglass beads reduces the mechanical excitations transmitted to the MEDs through kinetic energy absorption. Two kinds of tests, a laboratory test and a 60 mm air-gun test, have been made. The laboratory test using a vibration exciter up to 25 kHz has demonstrated that the cut-off frequency (2.2–15.8 kHz) and roll-off steepness (−155.0 to −78.7 dB decade −1 ) are inversely proportional to the diameter of the close-packed microglass beads (68–875 µm), whereas the vibration absorptivity (0.23–0.87) is proportional. The 60 mm air-gun test under high- g environments of up to 60 000 g has verified that the woodpecker-inspired SI is superior in improving the shock survivability of the MEDs to the conventional one using hard resin.
No takes yet. Share an insight, caveat, or question.
Yoon et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: