Why the study?
Prosthesis oversizing is recommended for the SAPIEN 3 valve to ensure device success, but midterm outcomes after transapical-TAVR with oversized valves needed investigation.
Does an oversized SAPIEN 3 prosthesis improve midterm outcomes compared to a non-oversized prosthesis in patients undergoing TA-TAVR?
Does an oversized SAPIEN 3 prosthesis improve midterm outcomes compared to a non-oversized prosthesis in patients undergoing TA-TAVR?
Answers are grounded in this paper and cite their sources.
Oversizing the SAPIEN 3 valve during TA-TAVR reduces paravalvular leak and the need for postdilation but increases the risk of permanent pacemaker implantation, with comparable midterm mortality.
BACKGROUND: A certain degree of prosthesis oversizing is recommended for the SAPIEN 3 (S3; Edwards Lifesciences Corp., Irvine, California, United States) to ensure device success. We aimed to investigate midterm outcomes in patients who received oversized (OS) S3 valve after transapical-transcatheter aortic valve replacement (TA-TAVR). METHODS: Out of 122 patients with aortic stenosis who underwent TA-TAVR using S3 at our institution, 42 received OS prosthesis. We used computed tomography (CT) derived effective diameter to assess oversizing. We defined oversizing if the labeled diameter of the selected valve for implantation was ≥2 mm bigger than the effective annulus diameter calculated by the annulus area. We conducted a midterm follow-up and compared the OS cohort with the non-OS (nOS) cohort. RESULTS: The study groups showed similar risk score and age (STS [Society of Thoracic Surgery] score: 5.4 ± 3; mean age: 80.7 ± 5.7). The 30-day mortality was 7.1% in OS versus 2.4% in nOS. The 30-day all-stroke was 2.4% in OS versus 0% in nOS. The 1- and 3-year all-cause mortality were 28.5 and 42.8% in OS versus 21.9 and 26.8% in nOS, respectively. Midterm freedom from death and from cardiocerebral events was similar in both groups. Moderate/severe paravalvular leakage occurred in 0% in OS versus 5.4% in nOS. The postdilation rate was 7.1% in OS versus 15.3% in nOS. The rate of new permanent pacemaker implantation (PPI) was 15.7% in OS versus 9.3% in nOS. The STS score was detected as an independent predictor of mortality. CONCLUSION: Oversizing reduces the risk of device failure and intraprocedural postdilation but increases the risk of PPI. Early and midterm morbidity and mortality after OS and nOS with S3 are comparable.
No takes yet. Share an insight, caveat, or question.
Useini et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: