Why the study?
Although stent-graft insertion is widely used alongside surgery to treat thoracic and abdominal aortic aneurysms, its use remains controversial in descending aortic dissection.
Case Report (n=1)
No
Answers are grounded in this paper and cite their sources.
Endovascular stent-graft insertion can serve as a viable alternative to high-risk open surgery for patients with chronic descending aortic dissection complicated by aortic enlargement and impending rupture.
Recently, stent-graft insertion has been widely used along with surgery for treatment of thoracic and abdominal aortic aneurysm.However, use of stent-graft insertion is controversial in descending aortic dissection.We report here on our experience of a patient who received a stent-graft for descending aortic dissection that nearly ruptured.Based on CT findings at three months follow up, results were satisfactory.
No takes yet. Share an insight, caveat, or question.
Woo et al. (2010) conducted a case report in Descending aortic dissection with intimal tear of the aortic isthmus and impending rupture (n=1). Endovascular stent-graft insertion (36x135 mm SEAL stent-graft) was evaluated on False lumen thrombosis, descending thoracic aorta size reduction, and symptom resolution on CT follow-up at 3 months (91 days).