The objective was to develop a simple routine method for quantitative measurement of endogenous formic acid in plasma and whole blood using headspace gas chromatography-flame ionization detection. (GC-FID). Two-hundred microliters of sample was placed in a 1-mL glass vial. Fifty microliters of aqueous ethanol (10%) was added as an internal standard and a derivatizing agent. Ethylformate formation was enhanced by addition of 200 microL concentrated sulfuric acid as a catalyst. The vials were then sealed immediately and placed in a water bath for 15 min at 60 degrees C. One milliliter of this headspace gas was siphoned using a gas-tight syringe and injected into a GC-FID fitted with a capillary column. Ethanol eluted at approximately 3.0 min, and ethylformate eluted around 4.7 min. The limit of quantitation for ethylformate was 0.026 mmol/L, and the limit of detection was 0.020 mmol/L. Imprecisions for spiked plasma samples at 0.25 and 1 mmol/L were 10% and 9%, respectively and recoveries were at 100% and 108%, respectively. A simple, reliable, and highly specific headspace analysis method for quantifying endogenous formate without the use of a headspace analyzer was developed. This method enables the routine clinical analysis of formate in plasma and whole blood samples.
No takes yet. Share an insight, caveat, or question.
Sokoro et al. (2007) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: