Trends in negative pressure over a few thousand cavitation events have been investigated for a Berthelot system comprising water/stainless steel/tube/sealing Ni plug in order to study the effects and extents of surface pre-treatments for the sealing metal, polishing, etching, and electroplating. The polishing and etching pre-treatments separated two kinds of cavitation nuclei on the metal surface; gases trapped within pores (crevices) (i) in the metal surface, and (ii) extending deep into the metal bulk. The latter, although much tougher, influenced negative pressure for a thousand cavitation events at most. The rise in negative pressure after a total of 1800 temperature cycles levelled off at around -115 bar (-11.5 MPa) irrespective of the surface finishes of the plugs. Electroplated plugs gave poor increasing trends owing to the co-deposited hydrogen. Impurity gases in the metal did limit the rise in negative pressure. These results, together with those reported before, have validated the authors extended gas-trapping crevice model, negative pressure is eventually limited by a supply of gas from sources in the metal bulk to surface crevices.
No takes yet. Share an insight, caveat, or question.
Ohde et al. (1992) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: