A portable cryogenic collection system has been constructed for the isolation of atmospheric nitrous oxide (N 2 O) and carbon monoxide (CO). Ambient air enters the system at a rate of 10 L/min, and N 2 O condenses in a specially designed stainless steel ultrahigh-efficiency collection (UHEC) trap. The CO is next oxidized to CO 2 and removed by a second UHEC trap. In conjunction with drying agents, the UHEC traps remove greater than 99.9989% of atmospheric carbon dioxide (CO 2 ) that would otherwise interfere with CO-derived CO 2 analysis. The oxygen in the N 2 O and CO-derived CO 2 samples is subsequently separated for high-precision mass spectroscopic analysis. This system is unique in that it provides for in situ collection and permits simultaneous measurement of the 18 O/ 16 O and 17 O/ 16 O ratios in N 2 O and CO. Results are presented for a series of trials run to determine the ultimate collection efficiency of the UHEC cryogenic traps.
No takes yet. Share an insight, caveat, or question.
Huff et al. (1997) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: