A prospective study was conducted on 25 Legionella pneumophila culture-positive and 98 culture-negative bronchoalveolar lavage fluid samples to compare two DNA preparation methods: a rapid modified Chelex-based protocol and a proteinase K method. PCR was found to be more sensitive with the Chelex-based method (P = 0.03). N difference was found concerning the inhibition rate.
No takes yet. Share an insight, caveat, or question.
Jaulhac et al. (1998) studied this question.