Why the study?
A novel micro-electrode catheter allowing very high-power short-duration (90 W/4 sec) ablation potentially offers safe, effective, and faster CTI ablation for typical AFL, but its feasibility and efficacy required evaluation.
Is very high-power short-duration (90 W/4 sec) temperature-controlled radiofrequency ablation feasible and effective for achieving cavotricuspid isthmus block in patients with typical right atrial flutter?
Is very high-power short-duration (90 W/4 sec) temperature-controlled radiofrequency ablation feasible and effective for achieving cavotricuspid isthmus block in patients with typical right atrial flutter?
Very high-power short-duration (90 W/4 sec) radiofrequency ablation is a feasible, efficient, and safe method for achieving cavotricuspid isthmus block in patients with typical atrial flutter.
Answers are grounded in this paper and cite their sources.
vHP-SD CTI ablation appears feasible in AFL; hypothesis-generating and requires randomized trials before adoption.
Funding Acknowledgements Type of funding sources: None. Background Catheter ablation for typical right atrial flutter (AFL) provides an effective treatment associated with encouraging clinical outcome. The novel micro-electrode ablation catheter allows very high-power short-duration (vHP-SD, 90 W/4 sec) ablation and potentially offers the ability to perform a safe, effective and faster cavotricuspid isthmus (CTI) ablation. Aims We evaluated feasibility and efficacy of a vHP-SD (90 W/4 sec) temperature-controlled radiofrequency (RF) CTI ablation for AFL using a novel contact force (CF) sensing ablation catheter with micro-electrodes. Methods Fifteen consecutive patients (median age 75 years (interquartile range, IQR: 67, 79), 67 % male) with documented typical AFL were prospectively enrolled and underwent vHP-SD based CTI ablation (90 W/4 sec). Durability of CTI block was proven by pacing maneuvers from both sides of the ablation line. Results Complete CTI block using vHP-SD ablation was achieved in all patients (Figure 1). At median 23 (IQR 20; 39) RF applications over a median RF ablation time of 92 (IQR 78, 154) seconds were applied. It was not necessary to switch to the standard temperature-controlled mode to achieve durable CTI block. No periprocedural complications, no charring and no steam pops were observed. Conclusions Very high-power short-duration (90 W/4 sec) CTI ablation for the treatment of typical AFL is feasible and efficient. Effective CTI block can be achieved in about 1.5 minutes of RF time.
No takes yet. Share an insight, caveat, or question.
Kirstein et al. (2022) studied this question.