Key result
Partial volume correction improves CT calcium volume accuracy and inter-reconstruction agreement over standard thresholding.
Observational (n=293)
Answers are grounded in this paper and cite their sources.
Shows that partial volume correction improves coronary calcium quantification accuracy in phantoms and chest CT, indicating reduced interscan variability.
INTRODUCTION: The amount of coronary artery calcium determined in CT scans is a well established predictor of cardiovascular events. However, high interscan variability of coronary calcium quantification may lead to incorrect cardiovascular risk assignment. Partial volume effect contributes to high interscan variability. Hence, we propose a method for coronary calcium quantification employing partial volume correction. METHODS: Two phantoms containing artificial coronary artery calcifications and 293 subject chest CT scans were used. The first and second phantom contained nine calcifications and the second phantom contained three artificial arteries with three calcifications of different volumes, shapes and densities. The first phantom was scanned five times with and without extension rings. The second phantom was scanned three times without and with simulated cardiac motion (10 and 30 mm/s). Chest CT scans were acquired without ECG-synchronization and reconstructed using sharp and soft kernels. Coronary calcifications were annotated employing the clinically used intensity value thresholding (130 HU). Thereafter, a threshold separating each calcification from its background was determined using an Expectation-Maximization algorithm. Finally, for each lesion the partial content of calcification in each voxel was determined depending on its intensity and the determined threshold. RESULTS: Clinical calcium scoring resulted in overestimation of calcium volume for medium and high density calcifications in the first phantom, and overestimation of calcium volume for high density and underestimation for low density calcifications in the second phantom. With induced motion these effects were further emphasized. The proposed quantification resulted in better accuracy and substantially lower over- and underestimation of calcium volume even in presence of motion. In chest CT, the agreement between calcium scores from the two reconstructions improved when proposed method was used. CONCLUSION: Compared with clinical calcium scoring, proposed quantification provides a better estimate of the true calcium volume in phantoms and better agreement in calcium scores between different subject scan reconstructions.
No takes yet. Share an insight, caveat, or question.
Šprem et al. (2018) conducted an observational in Coronary artery calcification (n=293). Partial volume correction method using Expectation-Maximization thresholding vs. Standard clinical calcium scoring using 130 HU intensity value thresholding was evaluated on Accuracy of coronary calcium volume estimation in phantoms and inter-reconstruction agreement of calcium scores in chest CT. Partial volume correction improved calcium volume accuracy in phantoms and agreement across reconstructions in 293 chest CT scans compared with standard 130 HU thresholding.
Synapse has enriched 10 related papers. Consider them for comparative context: