Perforation of the uterus by an intrauterine device (IUD) is a serious complication occurring at or following 1/350 to 1/2,500 insertions. It is more common among women with 'lost' IUDs. If a woman presents with pelvic pain and a history of a 'lost' IUD, X-rays of the abdomen and of the pelvis should be ordered. We report on a 'lost' IUD that had been inserted 12 years previously. It was found in the lower anterior abdominal wall. Most probably uterine perforation had happened during a dilatation and curettage (D & C) attempted for removal of the device. Thereafter the IUD must have migrated to the abdominal wall. This case illustrates that unless it can be recovered by simple traction on the threads, a trained medical professional should be called upon for removal of the IUD.
No takes yet. Share an insight, caveat, or question.
Mülayim et al. (2006) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: