Studies of nerve regeneration in rodents utilize at least one of three classes of outcome measures: electrophysiology, morphometry, and functional tests. The assumption that these measures are correlated was tested utilizing a data set of 16 variables. Significant correlations (Spearman's rho, P < or = 0.05) were found within variable classes; however, none were found between classes. The three commonly utilized outcome measures do not measure the same phenomenon but rather discrete aspects of nerve regeneration.
No takes yet. Share an insight, caveat, or question.
Munro et al. (1998) studied this question.