Why the study?
What are the 1-year complication rates following de novo pacemaker, ICD, and CRT implantation when accounting for mortality censoring?
What are the 1-year complication rates following de novo pacemaker, ICD, and CRT implantation when accounting for mortality censoring?
This prospective cohort study provides real-world 1-year complication rates for de novo cardiac rhythm management devices, demonstrating that CRT devices have the highest complication rate (7.64%) and highlighting the utility of mortality censoring for accurate reporting.
Higher CRT complication rates warrant caution in device selection; extends real-world evidence but leaves causal risks open for randomized confirmation.
Introduction Cardiac rhythm device implantation rates continue to grow, yet procedure complications are inadequately reported. Accurate reporting is necessary to generate quality standards as a benchmark for consultant revalidation. We present complication rates within the first year following de novo pacemaker (PPM), defibrillator (ICD) and cardiac resynchronisation (CRT) implant procedures. Mortality censoring is introduced as a novel method for analysing such data. Methods Between April 2008–March 2011, consecutive virgin PPM, ICD and CRT device implants were prospectively followed for 1 year post implant for pre-defined complications. Results 2614 new devices were implanted. Mean patient follow-ups were 0.94, 0.98 and 0.95 years for PPM, ICD and CRT devices respectively. Abstract 17 Table 1 Complications according to device category PPM (n = 1224) ICD (n = 512) CRT (n = 878) Pneumothorax 7 (0.57%) 4 (0.78%) 4 (0.46%) Pericardial effusion 1 (0.08%) 0 (0.00%) 2 (0.23%) Haematoma surgical evacuation 0 (0.00%) 1 (0.20%) 0 (0.00%) Device pocket revision 4 (0.33%) 6 (1.17%) 3 (0.34%) Lead intervention 30 (2.45%) 10 (1.95%) 47 (5.35%) System explant 6 (0.49%) 1 (0.20%) 7 (0.80%) System re-implant 5 (0.41%) 0 (0.00%) 4 (0.46%) Device upgrade 11 (0.90%) 2 (0.39%) 0 (0.00%) Total 64 (5.23%) 24 (4.69%) 67 (7.64%) Mortality at 1 year after PPM, ICD or CRT implant was 9.43%, 4.40% and 10.38%. Abstract 17 Table 2 Mortality censored complications (CI; confidence intervals) PPM (CI) ICD (CI) CRT (CI) Pneumothorax 0.61 (0.24 – 1.25) 0.08 (0.22 – 2.05) 0.48 (0.13 – 1.23) Pericardial effusion 0.09 (0.00 – 0.48) 0.00 (0.00 – 0.74) 0.24 (0.03 – 0.87) Haematoma surgical evacuation 0.00 (0.00 – 0.32) 0.20 (0.01 – 1.11) 0.00 (0.00 – 0.44) Device pocket revision 0.35 (0.09 – 0.89) 1.20 (0.44 – 2.61) 0.36 (0.07 – 1.05)
No takes yet. Share an insight, caveat, or question.
Brough et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: