A newly developed finite-element model accurately simulates pulsatile flow and pressure dynamics in flexible obstructed tubes, which may aid in understanding hemodynamics in stenotic vessels.
A finite-element model for pulsatile flow in a straight flexible partially obstructed tube is developed. In the unobstructed sections of the tube the model considers the continuity equation, the one-dimensional momentum equation, and an equation of state relating tube cross-sectional area to pressure. For the obstructed region, a nonlinear relationship between the flow and the pressure drop across the stenosis is considered. The applicability of a model is checked by comparing predicted flow and pressure waveforms with corresponding in-vitro experimental measurements obtained on a mechanical system. These comparisons indicated that the model satisfactorily predicts pressures and flows under variety of frequencies of oscillation and stenosis severities.
No takes yet. Share an insight, caveat, or question.
Rooz et al. (1982) studied this question.