Key result
Non-linear ECG normalization achieves ~99% resting authentication accuracy.
Why the study?
ECG morphological changes driven by physical and psychological factors can impede biometric authentication under fluctuating heart rates.
Does non-linear normalization of ECG beats improve biometric authentication accuracy and waveform similarity across various physiological conditions in healthy adults?
Does non-linear normalization of ECG beats improve biometric authentication accuracy and waveform similarity across various physiological conditions in healthy adults?
Non-linear segment-by-segment time normalization of ECG waveforms improves biometric user authentication accuracy across mild-to-moderate physiological heart rate fluctuations, though further amplitude normalization is needed for high-heart-rate exercise conditions.
The development and use of wearable devices require high levels of security and have sparked interest in biometric authentication research. Among the available approaches, electrocardiogram (ECG) technology is attracting attention because of its strengths in spoofing. However, morphological changes of ECG, which are affected by physical and psychological factors, can make authentication difficult. In this paper, we propose authentication using non-linear normalization of ECG beats that is robust to changes in ECG waveforms according to heart rate fluctuations in various daily activities. We performed a non-linear normalization method through the analysis of ECG alongside heart rate, evaluating similarities and authenticating the performance of our new method compared to existing methods. Compared with beats before normalization, the average similarity of the proposed method increased 23.7% in the resting state and 43% in the non-resting state. After learning in the resting state, authentication performance reached 99.05% accuracy for the resting state and 88.14% for the non-resting state. The proposed method can be applicable to an ECG-based authentication system under various physiological conditions.
No takes yet. Share an insight, caveat, or question.
Hwang et al. (2021) studied Healthy adults without heart disease undergoing ECG-based biometric authentication (n=15). Non-linear normalization of ECG beats for biometric authentication vs. Existing ECG normalization methods and non-normalized ECG beats was evaluated on Authentication accuracy (ACC) in resting and non-resting states using Support Vector Machine with Gaussian kernel (SVM-G). Non-linear ECG beat normalization achieved 99.05% authentication accuracy in the resting state and 88.14% in the non-resting state.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: