Key result
2D echocardiography misclassifies ~11% of patients for ICD eligibility compared to CMR.
Why the study?
The study investigated the potential impact of performing 2DE compared to CMR for LVEF assessment on ICD eligibility.
Does two-dimensional transthoracic echocardiography accurately agree with cardiovascular magnetic resonance in assessing LVEF for implantable cardioverter-defibrillator eligibility in patients with nonischemic cardiomyopathy?
Cohort (n=166)
Blind assessment (examiners did not have access to the other examination)
No
Does two-dimensional transthoracic echocardiography accurately agree with cardiovascular magnetic resonance in assessing LVEF for implantable cardioverter-defibrillator eligibility in patients with nonischemic cardiomyopathy?
In patients with nonischemic cardiomyopathy, 2D echocardiography shows clinically relevant disagreement with cardiac MRI when evaluating LVEF thresholds for primary prevention ICD implantation, resulting in misassignment of eligibility in 10.5% to 14.6% of patients.
Answers are grounded in this paper and cite their sources.
2DE may misassign ICD eligibility in nonischemic cardiomyopathy; leaves open whether CMR should supplant echocardiography for LVEF thresholds.
Background: The aim of this study was to investigate the potential impact of performing two-dimensional echocardiography (2DE) compared to cardiovascular magnetic resonance (CMR) for left ventricular ejection fraction (LVEF) on implantable cardioverter defibrillator (ICD) eligibility. Methods: A prospective cohort of 166 consecutive patients with nonischemic cardiomyopathy (NICM) was designed to compare transthoracic 2DE and CMR imaging. Results: Echocardiography measurements have important differences and large limits of agreement compared to CMR, especially when assessing ventricle volumes, and smaller but relevant differences when assessing LVEF. The agreement between CMR and 2DE regarding the identification of subjects with EF <= 35, respectively <= 30, and thus eligible for an ICD measured by Cohen’s Kappa was 0.78 (95% CI: 0.68–0.88), p < 0.001, respectively 0.65 (95% CI: 0.52–0.78), p < 0.001. The disagreement represented 7.9%/11.3% of the subjects who had EF < 35%/< 30% as observed by CMR, who would have been classified as eligible for an ICD, resulting in an additional need to use an ICD. Moreover, 2.6%/3.3% would have been deemed eligible by echocardiography for an ICD. Conclusions: These measurement problems result in incorrect assignments of eligibility that may have serious implications on the quality of life and the prevention of death events for patients assessed for eligibility of an ICD.
No takes yet. Share an insight, caveat, or question.
Schiau et al. (2021) conducted a cohort in Nonischemic cardiomyopathy (NICM) (n=166). Two-dimensional transthoracic echocardiography (2DE) vs. Cardiovascular magnetic resonance (CMR) was evaluated on Agreement between CMR and 2DE in identifying subjects eligible for an ICD based on LVEF <= 35% (Cohen's Kappa 0.78, 95% CI 0.68-0.88, p=<0.001). Two-dimensional echocardiography showed substantial agreement with CMR for ICD eligibility at LVEF <=35% (Kappa 0.78) and <=30% (Kappa 0.65), but misclassified 10.5% and 14.6% of patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: