Key result
Transcatheter mitral valve implantation guided by 2D and 3D TEE was successful in 100% of patients with left atrial thrombus, with no embolic complications over a mean follow-up of 21 months.
Why the study?
Co-existing left atrial or left atrial appendage thrombus is considered a contraindication for transcatheter mitral valve-in-valve or valve-in-ring implantation, and guiding this procedure using 2D and 3D TEE had not been described.
Does 2D and 3D TEE guidance allow safe transcatheter mitral valve implantation in patients with LA/LAA thrombus?
Observational (n=12)
Does 2D and 3D TEE guidance allow safe transcatheter mitral valve implantation in patients with LA/LAA thrombus?
2D and 3D TEE guidance enables safe transcatheter mitral valve implantation via the apical approach in patients with LA/LAA thrombus, a condition traditionally considered a contraindication.
May permit apical transcatheter MV implantation despite LA thrombus; hypothesis-generating and requires prospective validation.
BACKGROUND: The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure. METHODS AND RESULTS: All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE. All were at high/prohibitive risk for redo operation and all refused surgery. Utilizing both 2D and 3DTEE, especially 3DTEE, guidewires and the prosthesis deployment system could be manipulated under direct vision into the LA avoiding any contact with the thrombus. The procedure was successful in all with amelioration of symptoms and no embolic or other complications over a mean follow-up of 21 months. CONCLUSION: Our study demonstrates the feasibility of successfully performing this procedure in pts with thrombus in LAA and/or LA body without any complications.
No takes yet. Share an insight, caveat, or question.
Elmarzouky et al. (2022) conducted an observational in Severe bioprosthetic mitral valve stenosis/regurgitation with co-existing left atrial thrombus (n=12). 2D and 3D TEE-guided transcatheter mitral valve implantation via apical approach was evaluated on Procedural success and absence of embolic or other complications. Transcatheter mitral valve implantation guided by 2D and 3D TEE was successful in 100% of patients with left atrial thrombus, with no embolic complications over a mean follow-up of 21 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: