This paper presents a novel noncontact measurement technique that entails using a single-compound triple complementary split-ring resonator (SC-TCSRR) to determine the complex permittivity and thickness of a material under test (MUT). The proposed technique overcomes the problem engendered by the existence of air gaps between the sensor ground plane and the MUT. In the proposed approach, a derived governing equation of the resonance frequencies is used to estimate the thickness and complex permittivity of the MUT by calculating the resonant frequency (f r) and magnitude response in a single-step noncontact measurement process. This study theoretically analyzed and experimentally verified a simple and low-cost SC-TCSRR measurement method for assessing materials in a noncontact method. For a 0.2-mm air gap, the experiments yielded average measurement errors of 4.32% and 5.05% for the thickness and permittivity, respectively. The proposed SC-TCSRR technique provides excellent solutions for reducing the effect of air-gap conditions on permittivity, thickness, and loss tangent in noncontact measurements.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: