Key result
CFD-based virtual angiograms accurately detected flow stagnation in intracranial aneurysms, demonstrating 91.18% agreement (Kappa 0.822) with independent visual DSA assessment.
Why the study?
The study was conducted to test whether CFD-based virtual angiograms could automatically discriminate between intracranial aneurysms with and without flow stagnation.
Does CFD-based virtual angiography accurately detect flow stagnation in intracranial aneurysms compared to visual DSA assessment?
Observational (n=48)
Blinded visual assessment
Does CFD-based virtual angiography accurately detect flow stagnation in intracranial aneurysms compared to visual DSA assessment?
CFD-based virtual angiograms can accurately and automatically detect flow stagnation in intracranial aneurysms, potentially aiding in rupture risk assessment without manual DSA inspection.
Answers are grounded in this paper and cite their sources.
Supports automated CFD detection of flow stagnation; leaves open clinical utility for aneurysm rupture risk assessment.
The goal of this study was to test if CFD-based virtual angiograms could be used to automatically discriminate between intracranial aneurysms (IAs) with and without flow stagnation. Time density curves (TDC) were extracted from patient digital subtraction angiography (DSA) image sequences by computing the average gray level intensity inside the aneurysm region and used to define injection profiles for each subject. Subject-specific 3D models were reconstructed from 3D rotational angiography (3DRA) and computational fluid dynamics (CFD) simulations were performed to simulate the blood flow inside IAs. Transport equations were solved numerically to simulate the dynamics of contrast injection into the parent arteries and IAs and then the contrast retention time (RET) was calculated. The importance of gravitational pooling of contrast agent within the aneurysm was evaluated by modeling contrast agent and blood as a mixture of two fluids with different densities and viscosities. Virtual angiograms can reproduce DSA sequences if the correct injection profile is used. RET can identify aneurysms with significant flow stagnation even when the injection profile is not known. Using a small sample of 14 IAs of which seven were previously classified as having flow stagnation, it was found that a threshold RET value of 0.46 s can successfully identify flow stagnation. CFD-based prediction of stagnation was in more than 90% agreement with independent visual DSA assessment of stagnation in a second sample of 34 IAs. While gravitational pooling prolonged contrast retention time it did not affect the predictive capabilities of RET. CFD-based virtual angiograms can detect flow stagnation in IAs and can be used to automatically identify aneurysms with flow stagnation even without including gravitational effects on contrast agents.
No takes yet. Share an insight, caveat, or question.
Hadad et al. (2023) conducted an observational in Intracranial aneurysms (n=48). CFD-based virtual angiograms (contrast retention time) vs. Digital subtraction angiography (DSA) visual assessment was evaluated on Agreement between CFD-based prediction of flow stagnation and independent visual DSA assessment (Kappa 0.822, p=<0.0001). CFD-based virtual angiograms accurately detected flow stagnation in intracranial aneurysms, demonstrating 91.18% agreement (Kappa 0.822) with independent visual DSA assessment.