We report quantitative, spatially resolved, laser-induced fluorescence (LIF) measurements of NO concentration ([NO]) in non-sooting, oxygen-enriched counterflow diffusion flames at atmospheric pressure. Three different flames containing 25%, 50%, and 100% CH 4 , respectively, in the fuel stream and 100%, 50%, and 35% O 2 , respectively, in the oxidizer stream are investigated at a global strain rate of 20 s m 1 . Excitation of NO is achieved at 224.45 nm in the n (0,0) band and detection is performed in a 2-nm region centered at 235.78 nm in the n (0,1) band. Excitation scans ensure no spectral background problems under the high-temperature conditions of oxygen enrichment. Detection scans obtained at the excitation wavelength verify no interferences from any other species, particularly O 2 . Quantitative axial profiles of [NO] are presented for all three flames. Linear LIF measurements are compared to laser-saturated fluorescence (LSF) measurements to assess the utility of a broadband LSF technique at temperatures approaching 3000 K. Numerical computations for all counterflow diffusion flames are conducted using OPPDIF with GRI Mech-3.0. The effect of gas-phase radiation is considered in the modeling. The results indicate excellent agreement between the measured and predicted NO concentrations for all three flames. A comparison of the linear LIF and LSF measurements also yields excellent agreement.
No takes yet. Share an insight, caveat, or question.
Naik et al. (2002) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: