Why the study?
Objective assessment of prosthetic PVL is complex and challenging even on TEE, motivating evaluation of the value of CMR in quantifying PVL in AVR or MVR.
Does cardiovascular magnetic resonance improve the quantification and stratification of prosthetic paravalvular leaks compared to transesophageal echocardiography?
Does cardiovascular magnetic resonance improve the quantification and stratification of prosthetic paravalvular leaks compared to transesophageal echocardiography?
CMR provides more accurate quantification of prosthetic paravalvular leaks than semi-quantitative TEE, frequently reclassifying severity and better predicting elevated heart failure biomarkers.
CMR may refine PVL quantification beyond TEE; leaves open routine adoption pending prospective outcome studies.
BACKGROUND: Objective assessment of prosthetic paravalvular leak (PVL) is complex and challenging even in transesophageal echocardiography (TEE). Our aim was to assess the value of cardiovascular magnetic resonance (CMR) in quantifying PVL in aortic (AVR) or mitral valve (MVR) replacement. METHODS: Thirty-one patients (62 ± 15.1 years, 63% males) with a preliminary diagnosis of significant PVL (AVR, n-23; MVR, n = 8) were recruited. The TEE PVL grading was based on the semi-quantitative (SQ) TEE according to the VARC II PVL classification (%PVL: mild < 10%; moderate 10%-30%; severe > 30%). Non-contrast CMR studies were acquired at 1.5 T with a quantitative approach (phase-contrast velocity encoded imaging). The CMR PVL severity was classified according to regurgitant fraction (RF: (1) mild ≤ 20%, (2) moderate 21%-39%, or (3) severe ≥ 40%). RESULTS: All patients revealed symptoms of heart failure (71%: New York Heart Association [NYHA] II; 91%: N-terminal pro-B-type natriuretic peptide [NT-proBNP] > 150 pg/ml) and typical cardiovascular disease risk factors. The SQ-TEE results revealed several categories: (1) mild (n = 5; 16%), (2) moderate (n = 21; 67%), and (3) severe (n = 5; 16%) PVL. However, CMR PVL RF reclassified the severity of PVL: (1) mild to moderate (in 80%), (2) moderate to severe (in 47%), and (3) severe to moderate (in 40%). The receiver operating characteristic analysis showed that SQ-TEE and CMR PVL-vol and -RF predicted the upper tertile of NT-proBNP (> 2000 pg/ml) with the best sensitivity for CMR parameters. CONCLUSION: The SQ-TEE showed moderate agreement with CMR and underestimated a considerable number of AVR or MVR-PVL.
No takes yet. Share an insight, caveat, or question.
Haberka et al. (2021) studied this question.