Answers are grounded in this paper and cite their sources.
In this study, the heat transfer and flow characteristics of TiO 2 ‐H 2 O nanofluids with TiO 2 mass fractions of 0.0, 0.1, 0.3, and 0.5 wt.% in corrugated and smooth double‐pipe heat exchangers were compared using numerical simulations. The results demonstrated that TiO 2 ‐H 2 O nanofluids effectively enhanced the heat transfer compared to deionized water, and that the heat exchange capacity gradually increased with the TiO 2 mass fraction. The corrugated pipe heat exchanger disturbed the fluid flow on both the shell side and pipe side, breaking the boundary layer and creating vortices in the corrugated zone. This provided a higher heat transfer capability than the smooth double‐pipe heat exchanger, but also increased the fluid flow resistance in the pipe. In general, the use of nanofluids and corrugated pipes was found to significantly improve the heat transfer efficiency of the double‐pipe heat exchanger.
No takes yet. Share an insight, caveat, or question.
Ding et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: