Why the study?
Does superior vena cava echocardiography using color Doppler predict lead fibrosis in patients with cardiovascular implantable electronic devices?
Does superior vena cava echocardiography using color Doppler predict lead fibrosis in patients with cardiovascular implantable electronic devices?
Superior vena cava echocardiography using color Doppler may serve as a valuable noninvasive screening tool to predict lead fibrosis and complex procedures prior to CIED lead extraction.
Turbulent SVC flow may signal fibrosis risk before CIED extraction; leaves open its value as a noninvasive predictor pending prospective studies.
BACKGROUND: Currently there is no noninvasive imaging modality used to risk stratify patients requiring lead extractions. We report the novel use of superior vena cava (SVC) echocardiography to identify lead fibrosis and complex cardiac implantable electronic device (CIED) lead extraction. With an aging population and expanding indications for cardiac device implantation, the ability to deal with the complications associated with chronically implanted device has also increased. METHODS: This was a retrospective analysis of Doppler echocardiography recorded in our outpatient Electrophysiology/Device Clinic office over 6 months. Images from 109 consecutive patients were reviewed. RESULTS: 62% (68/109) did not have a CIED and 38% (41/109) had a CIED. In patients without a CIED, 6% (4/68) displayed turbulent color flow by Doppler in the SVC, while 22% (9/41) of patients with a CIED displayed turbulent flow. Fisher's exact test found a statistically significant difference between the two groups (p value < 0.05). The CIED group was subdivided into 2 groups based on device implant duration (< 2 years vs. ≥ 2 years). Of the CIED implanted for ≥ 2 years, 27% (9/33) had turbulent flow in the SVC by Doppler, while no patients (0/8) with implant durations < 2 years demonstrated turbulent flow. Nine patients underwent subsequent lead extraction. A turbulent color pattern successfully identified all 3 patients that had significant fibrosis in the SVC found during extraction. CONCLUSION: Our data suggests that assessing turbulent flow using color Doppler in the SVC may be a valuable noninvasive screening tool prior to lead extraction in predicting complex procedures.
No takes yet. Share an insight, caveat, or question.
Yakish et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: