Placenta praevia and vasa praevia (VP) have been known to medical science for more than 200 years. Jean Lobstein (1777–1835) was a French surgeon, pathologist and obstetrician who is credited for describing the first case of rupture of vasa praevia (VP) in Strasbourg in 1801 (Archives de L'art des Accouchements, 1801, p. 320). When Miles H. Phillips, an obstetrician from Sheffield, described a case of rupture of a ‘velamentous’ vessel during labour in 1914 (J Obstet Gynaecol Br Emp 1914;26:224) he could do very little more than deliver a dead fetus. He noted ‘the doctor in attendance ruptured the membranes before the cervix was fully dilated’. This was associated with ‘free bleeding’ and the doctor ‘suspected a placenta praevia’ and called for his help. His examination of the placenta after delivery showed a velamentous insertion of the cord with a ruptured VP. A few years later, when caesarean delivery had become more widely available, Arthur J. McNair (1887–1964), a consultant obstetric surgeon at Guy's Hospital, was able to surgically deliver a live baby presenting with a ‘marginal placenta praevia and velamentous cord’ (Proc R Soc Med 1921;14:195–6). Like Phillips, he concluded that ‘rupturing of the membranes had resulted in tearing of a large vein’. Until the late 1960s, when ultrasound started to be used to diagnose placental pathologies such as hydatidiform moles and placenta localisation (Campbell et al. J Obstet Gynaecol Br Commonw 1968;75:1007–13), the diagnosis of placenta praevia and/or VP was exclusively clinical. The ‘classic’ fresh bleeding immediately after spontaneous or artificial rupture of the membranes suggested the rupture of a VP (also referred as the Benckiser's haemorrhage). Very often, the diagnosis was confirmed during a vaginal examination by feeling the pulsating fetal vessel near the internal os. This diagnostic approach is unreliable and can precipitate fetal haemorrhage by accidental rupture of the membranes and damage to the VP. Gianopoulos et al. (Obstet Gynecol 1987;69:488–91) were the first to report on the prenatal diagnosis of VP with ultrasound. The performance of ultrasound for diagnosing VP is considered excellent. However, the incidence of VP is low and most studies have been conducted in specialist centres. There are no prospective studies on the value of screening for VP in an unselected population. A systematic review of the incidence and risk factors of VP has indicated that 83% of the 325 cases reviewed have one or more risk factors including placenta praevia, bilobated placenta, succenturiate placental lobe, conception by assisted reproductive technologies and velamentous insertion of the cord (Ruiter et al. BJOG 2016; 123:1278–87). The current study has shown that velamentous cord insertion and abnormal placental morphology are strong markers of VP and therefore identification of cord insertion and placental shape should be part of the routine ultrasound examination at 12–14 and 20–23 weeks. There is no consensus about time of delivery in cases of VP but, unlike the time of Mr Phillips and Mr McNair, parents are aware of the condition (http://vasapraevia.co.uk/the-experts/) and know that prenatal diagnosis and early delivery can prevent ‘unnecessary’ death. None declared. Completed disclosure of interests form available to view online as supporting information. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
No takes yet. Share an insight, caveat, or question.
Jauniaux et al. (2016) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: