A quench protection system for a high-temperature superconducting (HTS) coil using Cu tape co-wound with an HTS tape was studied by numerical analysis using a thermal model of a coil winding pack. In normal operation, the voltage across the resistive zone V s in the HTS coil was monitored by measuring the voltage difference between the HTS coil and the co-wound Cu coil. When V s exceeded the quench detection voltage, the HTS coil was disconnected from the power supply and the energy stored in the HTS coil was dumped into a dump resistor. At the same time, the terminals of the co-wound coil were connected to another resistor, and some of the current in the HTS coil was quickly transferred to the co-wound Cu tape coil due to the tight magnetic coupling of both coils. This is expected to decrease the hot-spot temperature due to the quick decrease of HTS coil current and to protect the coil from damage caused by overheating at the hot-spot. The analysis investigated the effectiveness of this method.