Answers are grounded in this paper and cite their sources.
We have developed electrolyte-gated sensors based on a field-effect transistor (FET) consisting of horizontally aligned single-walled carbon nanotubes (CNTs) synthesized on single-crystal quartz. Dense well-aligned CNTs serving as device channels enabled high current and large transconductance. Owing to these excellent device properties, the pH resolution was much better in the aligned-channel CNTFETs than in single-channel devices. For immunosensing, selective detection of human immunoglobulin E (IgE) by using aptamer-functionalized CNTFETs was demonstrated in the presence of nontarget proteins at much higher concentration. Moreover, measurements of sensor response versus IgE concentration produced data that fit well to the Langmuir adsorption isotherm. The developed sensors with aligned channels exhibited a drain current of 400-fold that of single-channel devices. Therefore, aligned-channel CNTFETs are useful for highly sensitive and practicable solution sensing.
No takes yet. Share an insight, caveat, or question.
Okuda et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: