Key result
Transcatheter aortic valve replacement significantly decreased plasmatic superoxide anion levels from baseline (0.648) to 10 minutes post-procedure (0.590, p<0.001), with reductions persisting at 30 days.
Why the study?
ROS are linked to aortic stenosis development and severity, but the time course and impact of ROS assessed by plasmatic superoxide anion in patients undergoing TAVR were unknown.
Does transcatheter aortic valve replacement reduce oxidative stress assessed by plasmatic superoxide anion in patients with aortic stenosis?
Observational (n=106)
Does transcatheter aortic valve replacement reduce oxidative stress assessed by plasmatic superoxide anion in patients with aortic stenosis?
TAVR is associated with an immediate and sustained decrease in oxidative stress, suggesting that superoxide anion could serve as a novel biomarker in aortic stenosis.
Answers are grounded in this paper and cite their sources.
TAVR-linked superoxide drop warrants no practice change; leaves open prognostic relevance in aortic stenosis.
Reactive oxygen species (ROS) are central bioenergetic markers linked to aortic stenosis (AS) development and severity. We sought to evaluate the time course and impact of ROS assessed by plasmatic superoxide anion (SA) among patients undergoing transcatheter aortic valve replacement (TAVR). Among 106 patients, SA significantly decreased after TAVR. Dropped values were measured 10 min after TAVR (0.590 ± 0.181 vs. 0.648 ± 0.193; p < 0.001) and persistent at 3 days (0.611 ± 0.0.228 vs. 0.646 ± 0.199; p = 0.033) and 30 days follow-up (0.572 ± 0.207 vs. 0.639 ± 0.199; p = 0.005). Increased baseline SA (>75 percentile) was continuously associated with higher postprocedural SA values 10 min after valve expansion (p < 0.001), at 3 days (p < 0.001) and 30 days (p < 0.001). Higher baseline SA was linked to higher inflammatory response assessed by higher C-reactive protein values at day 1 and day 3. The composite endpoint of all-cause mortality and/or stroke and/or pacemaker implantation and/or significant paravalvular aortic regurgitation ≥mild at 30 days did not differ significantly according to SA baseline values (p = 0.055). This is the first report identifying a decrease in oxidative stress level after TAVR. Our observation leads to the hypothesis that oxidative stress biomarkers may survive the journey from bench to bedside in AS and TAVR and become new biomarkers with both diagnostic and prognostic values. Antioxid. Redox Signal. 31, 420–426.
No takes yet. Share an insight, caveat, or question.
Marchandot et al. (2018) conducted an observational in Aortic stenosis (n=106). Transcatheter aortic valve replacement (TAVR) vs. Baseline (pre-procedure) was evaluated on Plasmatic superoxide anion (SA) levels 10 minutes after TAVR (p=<0.001). Transcatheter aortic valve replacement significantly decreased plasmatic superoxide anion levels from baseline (0.648) to 10 minutes post-procedure (0.590, p<0.001), with reductions persisting at 30 days.