Coated conductor Roebel cables are an effective way to create a high current density, fully transposed cable. However, despite REBCO tapes being robust against transverse stress, the Roebel architecture can concentrate transverse stress in non-trivial and random patterns depending on the exact arrangement of strands. If stands are embedded in a solid media which consolidates all strands then a transverse stress concentration will not occur. We tested this idea through mechanical and thermo-cycling tests on 5 strand Roebel cables. For non-impregnated cable irreversible degradation in critical currents is initiated at transverse pressures in a range of 4–34 MPa. Optical examination of the cables shows stress concentration patterns beyond those predicted by thickness variations. For cables impregnated with epoxy filled with SiO 2 nanopowder, which has a similar thermal expansion coefficient to the metallic substrate of the strands, the irreversibility point is increased above our highest experimentally available pressure of 270 MPa. Thermo-cycling experiments confirmed a closely matched thermal expansion coefficient between the embedding media and metallic substrate is critical to avoid wire failures.
No takes yet. Share an insight, caveat, or question.
Talantsev et al. (2017) studied this question.