Why the study?
Does the E/e' ratio measured by transesophageal echocardiography reliably estimate pulmonary capillary wedge pressure in cardiac surgical patients?
Does the E/e' ratio measured by transesophageal echocardiography reliably estimate pulmonary capillary wedge pressure in cardiac surgical patients?
In cardiac surgical patients, the E/e' ratio measured by transesophageal echocardiography correlates only modestly with pulmonary capillary wedge pressure and is not a reliable noninvasive surrogate.
E/e' should not guide PCWP estimation in cardiac surgical patients; observational data leave open validation of alternative noninvasive surrogates.
BACKGROUND: The pulmonary artery catheter (PAC) has historically been used to measure cardiac filling pressures of which pulmonary capillary wedge pressure (PCWP) has been used as a surrogate of left atrial pressure (LAP) and left ventricular end-diastolic pressure. Increasingly, the use of the PAC has been questioned in the perioperative period with multiple large studies unable to clearly demonstrate benefit in any group of patients, resulting in a declining use in the perioperative period. Alternative methods for the noninvasive estimation of left-sided filling pressures are required. Echocardiography has been used to provide noninvasive estimation of PCWP and LAP, based on evaluating mitral inflow velocity with the E and A waves and looking at movement of the mitral annulus with tissue Doppler (e'). AIM: The aim of our study was to assess the relationship between PCWP and E/e' in cardiac surgical patients with transesophageal echocardiography (TOE). DESIGN: A prospective observational study. SETTING: Cardiac surgical patients in a single quaternary referral university teaching hospital. METHODS: The ratio of mitral inflow velocity (E wave) to mitral annular tissue velocity (e') (the E/e' ratio) and PCWP of 91 patients undergoing general anesthesia and cardiac surgery were simultaneously recorded, with the use of TOE and a PAC. RESULTS: The correlation between E/e' and PCWP was modest with a Spearman rank correlation coefficient of 0.29 (P = 0.005). The area under the receiver operating characteristic curve for using E/e' to predict elevated PCWP (≥18 mmHg) was 0.6825 (95% confidence interval: 0.57-0.80), indicating some predictive utility. The optimum threshold value of E/e' was 10 which had 71% sensitivity and 60% specificity to predict a PCWP ≥18 mmHg. CONCLUSIONS: Noninvasive measurements of E/e' in general cardiac surgical patients have only a modest correlation and does not reliably estimate PCWP.
No takes yet. Share an insight, caveat, or question.
Cowie et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: