Advanced imaging techniques for early detection of malignant supratentorial infarcts are often inaccessible in resource-limited areas, prompting evaluation of optic nerve sheath imaging measurements for early risk stratification.
Does optic nerve sheath diameter (ONSD) measurement accurately detect malignant supratentorial infarcts in adult stroke patients?
Does optic nerve sheath diameter (ONSD) measurement accurately detect malignant supratentorial infarcts in adult stroke patients?
Optic nerve sheath diameter measurement provides high diagnostic accuracy for detecting malignant supratentorial infarcts, offering a noninvasive monitoring alternative in resource-limited settings.
ONSD ultrasound may aid early malignant infarct detection in resource-limited settings; leaves open need for prospective validation against advanced imaging.
INTRODUCTION: Early detection of malignant supratentorial infarcts, particularly malignant middle cerebral artery (MCA), is crucial; however, advanced imaging techniques such as MRI and PET are often inaccessible in resource-limited areas. A potential solution for early risk stratification of stroke patients is the optic nerve sheath diameter (ONSD) measured by transorbital ultrasound. The purpose of this study was to evaluate the utility of optic nerve sheath imaging measurements in recognizing malignant infarcts. A meta-analysis on ONSD measurement has been done for acute ischemic stroke patients. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2022 guidelines, a comprehensive search was conducted for studies published between January 2000 and December 2023. A total of six eligible studies were included. These studies were observational studies involving adult patients diagnosed with malignant supratentorial infarcts who underwent ONSD assessment using ultrasonography, computed tomography (CT), or magnetic resonance imaging (MRI). Data extraction and risk of bias assessments were performed independently. A meta-analysis was conducted to pool estimates of mean ONSD measurement, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy using the metamean() and metaprop() functions from the meta R package. RESULTS: Four studies (n = 170) show a high detection rate of 89.01% (95% CI: 82.88-93.13) with low heterogeneity (I² = 21.3%) based on CT findings of malignant middle cerebral artery (MCA) infarction or progression of acute ischemic stroke. Six studies (n = 314) reporting ONSD showed a pooled mean of 5.50 mm (95% CI: 5.24-5.76 mm), though heterogeneity was substantial (I² = 97.0%). Findings show a sensitivity of 89.01%, specificity of 82.94% to 86.63%, PPV of 81.37%, NPV of 92.57%, and overall diagnostic accuracy of 87.82%. An optimal ONSD cutoff value across studies of 4.70 mm to 5.60 mm, with 5.60 mm, demonstrates the highest diagnostic yield (Youden's Index = 0.8947). CONCLUSION: ONSD measurements can be used in determining malignant infarcts.
No takes yet. Share an insight, caveat, or question.
Eli Chu (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: