Answers are grounded in this paper and cite their sources.
In the six-step mode control of the interior permanent-magnet machine (IPMSM), inequality of the positive half-cycle length and the negative half-cycle length will bring about dc offset in the three-phase input current. This paper proposes a six-step mode control scheme of IPMSM for railway vehicle traction to eliminate the dc offset in input current. An approximately continuous rotor position signal is reconstructed in the field-programmable gate array chip. This position signal is used to generate the square drive signal for IPMSM in the flux-weaken region. Rotor position signal error of the resolver will also cause dc offset in the three-phase input current. A novel scheme using phase-locked loop to decrease the rotor position signal error is proposed. And using this scheme, the dc offset is eliminated from the three-phase input current. A seamless transition scheme from six-step mode control to space vector pulse width modulation (SVPWM) mode is proposed. The effectiveness of this six-step mode control scheme is proved by the experimental results.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: