Hot electron trapping can significantly modify the performance of GaN-based HEMTs during hard switching operation. In this letter, we present a physics-based model based on rate equations to model the trapping kinetics of hot-electrons in GaN transistors submitted to semi- ON-state stress. The model is validated through comparison with the experimental data, obtained by means of a pulsed-drain current transient setup developed ad-hoc. Hot-electron trapping is found to have logarithmic time dependence; the first 10 μs of operation are critical in determining the current collapse during stress.
No takes yet. Share an insight, caveat, or question.
Modolo et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: