In South Korea, where mountainous terrain accounts for a significant proportion of the country, tunnels are essential for reaching destinations via the shortest possible route. Tunnels are high-traffic areas with only two exits, making them vulnerable to large-scale disasters in the event of a fire. However, existing longitudinal-flow-type exhaust systems (jet fans) are insufficient for effective smoke exhaust during a tunnel fire. Herein, a new ventilation system is proposed that uses a device with nozzles for expelling high-speed winds to generate a more robust ventilation flow at a tunnel entrance. A computational fluid dynamics (CFD) analysis showed that a jet fan system had a wind speed of 1.52 m/s at the tunnel exit. This system removed a total of 37,053.9 kg of air in 600 s. By contrast, the proposed Bernoulli ventilation system had a wind speed of 1.85 m/s at the tunnel exit and removed 53,308.4 kg air in 600 s. The simulation results from a scaled-down model of the tunnel safety testing facility were compared with the CFD analysis results. The ratio of the wind speeds between the tunnel entrance and exit was 2.7:1, exhibiting a similar trend. In conclusion, this study experimentally verified a CFD analysis of a Bernoulli ventilation system and provided a direction for improving longitudinal-flow-type exhaust systems. The results can be a foundational resource for government agencies (such as the Road Traffic Authority) in improving current ventilation systems.
No takes yet. Share an insight, caveat, or question.
Hong et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: