Does an active fixation coronary sinus lead reduce dislocation rates and improve threshold stability compared to conventional passive fixation leads in patients requiring CS lead implantation?
Does an active fixation coronary sinus lead reduce dislocation rates and improve threshold stability compared to conventional passive fixation leads in patients requiring CS lead implantation?
The active fixation coronary sinus lead reduces dislocation rates and provides stable pacing thresholds compared to conventional passive leads, though its extraction can be highly challenging.
Active fixation CS leads may reduce dislocations; leaves open net benefit pending RCTs on extractability.
AIMS: Coronary sinus (CS) lead implantation is a technically challenging procedure owing to variable vein anatomies and a high dislocation rate. Therefore, CS lead technology has undergone evolutionary changes during the last 10 years. The mode of fixation has been a passive one up to now. We want to describe our first clinical experience with the newly available active fixation lead 4195 in terms of dislocation rate and stability of thresholds compared with conventional models. METHODS AND RESULTS: From 1999 to February 2007, we implanted 403 CS leads in 368 patients. Leads were categorized into three different groups on the basis of their fixation mechanism: straight (Easytrak I and Situs OTW; n = 54), curved (Attain 4193 and 4194, Corox, Aescula, Situs ULD; n = 308), and active (Attain 4195; n = 41). Operative and follow-up data were prospectively noted and checked for significance between groups during the first 3 months after implantation. Kaplan-Meier analysis of long-term lead function was also performed. Straight and curved CS leads suffered from significantly more dislocations compared with active fixation (P < 0.001). The active fixation lead (4195) has a stable threshold over time compared with a significant rise after 24 h and thereafter in straight (62%) and curved leads (20%). However, retraction of an active fixation CS lead may be a difficult issue as outlined in two cases requiring pullback of a 4195 lead owing to phrenic nerve stimulation (one unsuccessful despite vigorous traction). CONCLUSION: The active fixation lead 4195 using retention lobes yielded stable thresholds over time and seems to be superior to conventional leads in terms of dislocation. However, extraction may be a difficult or even impossible task.
No takes yet. Share an insight, caveat, or question.
Nägele et al. (2007) studied this question.