Key result
The Sigma Large Eddy Simulation model provided the best balance of accuracy and computational cost for simulating pulsatile post-stenotic flow compared to under-resolved direct numerical simulation.
Why the study?
Auscultation of carotid bruit has poor sensitivity for screening asymptomatic carotid stenoses, prompting interest in detecting neck skin vibrations, but robust computational fluid dynamics strategies capturing post-stenotic high-frequency fluctuations are needed.
The Sigma large eddy simulation model provides an optimal balance of accuracy and computational cost for simulating pulsatile post-stenotic carotid flow, which may aid future non-invasive diagnostic modeling of skin vibrations.
CFD modeling of post-stenotic vibrations shows promise for stenosis screening; leaves open clinical validation before practice change.
PURPOSE: Screening of asymptomatic carotid stenoses is performed by auscultation of the carotid bruit, but the sensitivity is poor. Instead, it has been suggested to detect carotid bruit as neck's skin vibrations. We here take a first step towards a computational fluid dynamics proof-of-concept study, and investigate the robustness of our numerical approach for capturing high-frequent fluctuations in the post-stenotic flow. The aim was to find an ideal solution strategy from a pragmatic point of view, balancing accuracy with computational cost comparing an under-resolved direct numerical simulation (DNS) approach vs. three common large eddy simulation (LES) models (static/dynamic Smagorinsky and Sigma). METHOD: We found a reference solution by performing a spatial and temporal refinement study of a stenosed carotid bifurcation with constant flow rate. The reference solution [Formula: see text] was compared against LES for both a constant and pulsatile flow. RESULTS: Only the Sigma and Dynamic Smagorinsky models were able to replicate the flow field of the reference solution for a pulsatile simulation, however the computational cost of the Sigma model was lower. However, none of the sub-grid scale models were able to replicate the high-frequent flow in the peak-systolic constant flow rate simulations, which had a higher mean Reynolds number. CONCLUSIONS: The Sigma model was the best combination between accuracy and cost for simulating the pulsatile post-stenotic flow field, whereas for the constant flow rate, the under-resolved DNS approach was better. These results can be used as a reference for future studies investigating high-frequent flow features.
No takes yet. Share an insight, caveat, or question.
Mancini et al. (2019) studied Carotid stenosis (n=1). Large Eddy Simulation (LES) models (Sigma, Dynamic Smagorinsky) vs. Under-resolved Direct Numerical Simulation (DNS) was evaluated on Replication of high-frequent flow fluctuations (turbulent kinetic energy). The Sigma Large Eddy Simulation model provided the best balance of accuracy and computational cost for simulating pulsatile post-stenotic flow compared to under-resolved direct numerical simulation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: