This study focuses on the anaerobic treatment of sulfate-containing municipal wastewater at 20 °C with a fluidized bed reactor. Mean influent chemical oxygen demand (COD) and sulfate concentrations were 481 and 96 mg/l. The response of the COD removal efficiency to increasing organic loading rates (OLR) was investigated. Average total COD removal was 61% at OLR between 2.7 and 13.7 kg COD/(m³·d) and did not distinctly depend on the OLR. To assess the removal efficiency in more detail the COD in- and output mass flows were balanced. The results showed that only 11-12% of the input COD was recovered as gaseous methane. About 12-13% of the input COD remained in the effluent as dissolved methane. Furthermore, a distinct amount of 12-19% of the input COD remained in the reactor as settled sludge and was not further biologically degraded. Due to the reduction by sulfate-reducing bacteria, 13-14% of the input COD was degraded. Further adverse impacts of the influent sulfate on the anaerobic treatment process are discussed as well.
No takes yet. Share an insight, caveat, or question.
Düppenbecker et al. (2016) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: