Partial discharge (PD) is widely recognized as the early sign of fatal insulation failure of high-voltage (HV) power equipment and is considered a major factor in accelerating insulation degradation. However, the detection of weak PD signals in noisy environments and the identification of PD modes based on poor-quality data are rather challenging. In this work, using compact and implantable optical detection tools, optical emission spectroscopy (OES) and phase-resolved (PR) ultraviolet (UV) are combined to monitor PD. Based on the obtained dataset, a Transformer-based deep learning model is built and its recognition performance is optimized to realize the fast recognition and classification of spark, corona, and surface flashover, with a precision of 100% and an accuracy of 99%. This capability will help to alarm potential HV equipment failure and assess the risk in advance.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2024) studied this question.