Continuous glucose monitoring (CGM) has been demonstrated in randomized trials to improve glucose control in patients with type 1 diabetes (T1D) (1–3); however, most of the participants in these trials have used a pump for insulin delivery, and the use of CGM in T1D patients receiving insulin by injection has not been well studied. We used the T1D Exchange registry database to assess the impact of CGM on HbA1c in insulin injection users. Details on the informed consent process, eligibility criteria, and data collection methods have been previously published (4). Participants were defined as CGM users if CGM was used for real-time diabetes management during the 30 days prior to the clinic visit. Among the 17,731 registry participants with T1D duration >1 year who had a clinic visit between June 2014 and October 2015, 6,222 (35%) used injections alone, 8,783 (50%) used pump alone, 2,316 (13%) used pump with CGM, and 410 (2%) used injections with CGM. A Dexcom CGM was being used by …