Why the study?
USAT is advocated for pulmonary embolism based on the hypothesis of superior clinical efficacy over standard CDT, prompting a comparison of outcomes between modalities.
Does ultrasound-accelerated thrombolysis improve hemodynamics and clinical outcomes compared to standard catheter-directed thrombolysis in patients with pulmonary embolism?
Does ultrasound-accelerated thrombolysis improve hemodynamics and clinical outcomes compared to standard catheter-directed thrombolysis in patients with pulmonary embolism?
Standard catheter-directed thrombolysis achieves similar hemodynamic and clinical benefits as ultrasound-accelerated thrombolysis for pulmonary embolism, suggesting expensive USAT devices may not be necessary.
Standard CDT yields similar PE outcomes to USAT; leaves open whether randomized data would confirm equivalence or alter practice.
Ultrasound-accelerated thrombolysis (USAT) is advocated in pulmonary embolism (PE) based on the hypothesis that adjunctive ultrasound provides superior clinical efficacy compared to standard catheter-directed thrombolysis (CDT). This retrospective study was designed to compare outcomes between the two modalities. We analyzed patients with computed tomography-diagnosed PE at our institution treated with either USAT or standard CDT. Efficacy parameters assessed included invasive pulmonary artery systolic pressure (PASP; pre- and 24 hours post-treatment), non-invasive right-to-left ventricle (RV/LV) ratio (pre- and post-treatment), and general clinical outcomes (length-of-stay, significant bleeding, and mortality). We analyzed 98 cases (62 USAT and 36 CDT), in whom massive PE was diagnosed in 7%, intermediate/high risk in 81%, and intermediate/low risk in 12%. Overall, 92% had bilateral clot and 40% saddle embolus. At 24 hours, PASP decreased similarly in both groups (CDT Δ14.7 mmHg, USAT Δ10.8 mmHg; p = 0.14). Post-treatment, CDT showed similar improvement in the RV/LV ratio (CDT Δ0.58 vs USAT Δ0.45; p = 0.07), despite the baseline ratio being greater in the CDT group, indicating more severe RV strain (1.56 ± 0.36 vs 1.40 ± 0.29; p = 0.01). Intensive care unit and hospital length-of-stays were similar in both groups. A trend toward lesser significant bleeding rates in the CDT group (8.3% vs 12.9%, p = 0.74) as well as improved survival-to-discharge (97.2% vs 91.9%, p = 0.66) was observed. Compared to USAT, standard CDT achieves similar beneficial effects on hemodynamics, RV/LV ratios, and clinical outcomes. These observations suggest that salutary clinical results may be achieved without the need for very expensive devices.
No takes yet. Share an insight, caveat, or question.
Rothschild et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: