Answers are grounded in this paper and cite their sources.
Small vessels in three-dimensional MR angiograms have low visibility in maximum-intensity projection images because of their low contrast. In a previous study, we had two nonlinear filters that appeared to give significant improvement in small vessel detail. In this paper, we report on a generalization of this filter that allows a more general modeling of the vessels and a more complete suppression of background. One implementation of the general filter gave a vessel mean contrast-to-noise ratio that is 2.52 and 3.51 times higher than the vessel mean contrast-to-noise ratio obtained using our previously reported maximum-minimum (max-min) filter and cross-section filter, respectively.
No takes yet. Share an insight, caveat, or question.
Du et al. (1997) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: