Key result
A 3D-echo-guidance protocol using multiplanar reconstruction for transcatheter direct mitral valve annuloplasty yielded a 93.8% technical success rate and reduced device times over experience (P=0.018).
Why the study?
Transcatheter direct mitral valve annuloplasty requires demanding echocardiographic guidance for anchor positioning, but evidence on optimal peri-interventional imaging remains sparse.
Does a 3D-echo-guidance protocol using MPR improve procedural efficiency and safety in patients undergoing transcatheter direct mitral valve annuloplasty?
Observational (n=16)
No
Does a 3D-echo-guidance protocol using MPR improve procedural efficiency and safety in patients undergoing transcatheter direct mitral valve annuloplasty?
A real-time MPR-based 3D-echo-guidance protocol is feasible and safe for transcatheter direct mitral valve annuloplasty, significantly reducing implantation times with experience.
Answers are grounded in this paper and cite their sources.
Initial experience supports echo guidance feasibility for direct mitral annuloplasty; leaves open standardization and outcome assessment in larger trials.
OBJECTIVES: Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. METHODS: Overall, 16 patients consecutively treated with transcatheter direct annuloplasty for severe MR (87.5% functional/6.3% degenerative/6.3% mixed pathology) were entered in this monocentric analysis. Of these, two patients received a combined procedure including edge-to-edge repair. For all implantations, a 3D-echo-guidance protocol inheriting MPR was employed. RESULTS: Periprocedural device time decreased continuously (overall mean 140 ± 55.1 minutes, 213 ± 38 minutes in the first 4 vs 108 ± 33 minutes in the last 4 procedures, P = .018) using the MPR-based echo protocol, going along with reduced fluoroscopy times and doses. Technical success rate was high (93.8%) without any serious cardiac-related adverse events. MR could be relevantly improved. CONCLUSION: Echocardiographic guidance of transcatheter direct annuloplasty using a real time MPR-based protocol is feasible and safe. Optimized imaging might enable reduced implantation times and potentially increases safety.
No takes yet. Share an insight, caveat, or question.
Geyer et al. (2020) conducted an observational in Severe mitral regurgitation (n=16). 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) was evaluated on Technical success. A 3D-echo-guidance protocol using multiplanar reconstruction for transcatheter direct mitral valve annuloplasty yielded a 93.8% technical success rate and reduced device times over experience (P=0.018).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: